电动伸缩门的使用现在已经是非常普遍了,在长年累月的使用中,伸缩门也会出现一些大大小小的问题,比较常见的就是门之前好好的,下次用的时候,就不能用了,没反应,下面列举下几种解决办法:



The use of electric telescopic doors is very common now。 In the long-term use, there will also be some big and small problems in the telescopic doors。 The more common problem is that the door is well in front of the door。 The next time it is used, it will not be used。 There is no response。 Here are several solutions:



1、先检查电动伸缩门有没有漏电,保险管是否正常无烧坏现象,如果保险丝熔断了,就需要做全面检查,因为可能存在重大隐患;



1. First check whether the electric telescopic door is leaking and whether the fuse is normal without burning out. If the fuse is fused, a comprehensive inspection is needed, because there may be major hidden dangers.



2、把保安室的连接伸缩门的电源插头拔了,用万能表,测试红白黄三线的引线是否相通



2. Pull out the power plug connecting the telescopic door of the security room and use the universal meter to test whether the three wires of red, white and yellow are connected.





「乌海伸缩门维修」伸缩门不能正常运行的解决办法


Solutions to the Problem of "Telescopic Door Maintenance" Telescopic Door Failing to Run Normally



如红、白、黄三条线不通,再检测机尾接线盒里红、白、黄若相通,说明地下电缆中红、白、黄断路不相通


If the red, white and yellow lines are not connected, then the red, white and yellow lines in the terminal box are connected, indicating that the red, white and yellow lines in the underground cables are not connected.



再拆开机罩,电动门在门排与机头连接的插头处再测这三条线若相通,说明从门排端起至传达室的线断,若还是不通,直接测量电机定子线圈是否断路。


If the three wires are connected at the plug connecting the door row and the nose, it shows that the line from the end of the door row to the conveyor room is broken. If it is still not connected, the stator coil of the motor is directly measured whether the circuit is broken.



3、电动伸缩门电机引线只有红黄相通,和白色是不相通的,检查电机的定子温度是否异常,如果温度异常,就说明电机温度过高,启用保护机制,所以不能运行,如果温度正常,检查启动电容是否失效;


3。 Electric telescopic door motor lead only red and yellow, and white is not connected, check whether the motor stator temperature is abnormal, if the temperature is abnormal, it means that the motor temperature is too high, start protection mechanism, so it can not run, if the temperature is normal, check whether the starting capacitor is invalid;



4、如果电机情况正常,但是还是不能启动,检查三条线限位信号是否短路,因为如果限位短路,可能到导致信号错误,门就不能开关;



4. If the motor is in normal condition, but still can not start, check whether the three line limit signal is short-circuit, because if the limit short-circuit, may lead to signal errors, the door can not be switched;



5、电机线和限位信号线良好的话,还是不能开关,就说明是控制开关盒有故障,这时候检查下控制盒的内部是否有故障,如按钮坏了,或者里面断线就可以了。



5。 If the motor wire and limit signal line are good, or can't switch, it means that the control switch box is faulty。 At this time, check whether the internal of the control box is faulty, such as the button is broken, or the inside is broken。