「乌海无轨伸缩门定做」电动伸缩门漏电维护器装置办法



"Customized Trackless Suspension Door" Electric Telescopic Door Leakage Maintenance Device Method



伸缩门不断覆盖小区、学校、医院、政府等大门均有选用。但乌海伸缩门漏电事故却在近年一再呈现,造成了悲惨的事故。



Expansion doors are continuously used in residential areas, schools, hospitals, government and other gates. However, the leakage accident of telescopic doors has appeared again and again in recent years, resulting in tragic accidents.


怎样避免这些事故呈现?加装漏电维护器真能避免伸缩门漏电吗?



How to avoid these accidents? Is it really possible to avoid leakage of telescopic door by installing leakage maintainer?






首先应探求什么原因引发的漏电?


First of all, what causes the leakage should be explored?


据相关专家介绍,伸缩门的作业原理是利用电能提供伸缩的动力,而乌海伸缩门是直接暴漏在室外的,许多原因会引起伸缩门漏电,例如,阴雨雷电天气、线路老化问题、部分线路呈现故障等等。



According to relevant experts, the working principle of telescopic doors is to use electric energy to provide power for telescopic, and telescopic doors leak outdoors directly. Many reasons can cause telescopic doors leakage, such as rainy and thunderstorm weather, line aging problems, some line failure, and so on.


正是这一缝隙,对伸缩门增加漏电维护,这样一旦呈现漏电问题可以及时停机以免呈现事故。



It is this gap that increases leakage maintenance for expansion doors, so that once the leakage problem occurs, the machine can be stopped in time to avoid accidents。






伸缩门漏电维护器装置办法



Method of Leakage Maintenance Device for Telescopic Door


1、在装置的时候必须严厉的区分中性线和维护线,设备外壳要连接地线。



1. The neutral line and maintenance line must be strictly distinguished when installing the equipment. The equipment shell should be connected with the ground line.


漏电维护器的中性线应该接入漏电维护回路,接零维护线应该接入漏电维护器的中性线电源侧,不能接到负荷侧。



The neutral line of the leakage maintainer should be connected to the leakage maintenance circuit, and the zero maintenance line should be connected to the power side of the neutral line of the leakage maintainer, but not to the load side.


通过伸缩门漏电维护器后的中性线不能接设备外露的部分,设备外壳接地线应该单独接地。



The neutral line behind the leakage maintainer of the telescopic door can not connect the exposed part of the equipment. The grounding wire of the equipment shell should be grounded separately.


2、漏电维护器负载侧的中性线不能和其它回路并用。



2. The neutral line on the load side of leakage maintainer can not be used with other loops.


3、伸缩门漏电维护器标有负载侧和电源侧的时候,应该严厉的按照规定装置。



3. When the leakage maintainer of telescopic door is marked with load side and power side, it should strictly follow the stipulated device.


4、装置完伸缩门漏电维护器之后,不能撤掉低压供电线路和电气设备的接地维护措施。



4. After installing the leakage maintainer of telescopic door, the grounding maintenance measures of low-voltage power supply lines and electrical equipment cannot be removed.


5、乌海伸缩门漏电维护器装置结束之后,应该操作试验按钮,来查验一下漏电维护器的作业功能是否可以正常作业,如果一切正常,才可以投入使用。